  • Hp Smart Array Controller Software
    카테고리 없음 2021. 1. 15. 04:13


    Hp smart array controller software reviews

    Hi Support, We need HP Dynamic Smart Array B320i Controller drivers for HP ProLiant DL360 server Please provide the details ASAP Thanks - 6395594. Is The Dynamic Smart Array B120i Controller is a software based RAID solution? I really thought it;s hardware based RAID controller. But one external consult argue it is software based RAID solution according following. “HP Dynamic Smart Array is a RAID solution combining a storage host bus adapter (HBA) and proprietary software components.

    Print|Rate this content

    HP Smart Array controller. This utility is designed to enable a logical drive to be configured on a new HP server before the operating system is installed:. If the boot drive has not been formatted and the boot controller is connected to six or fewer physical.

    Chicony usb 2.0 camera driver. Sep 17, 2015  Chicony USB 2.0 Camera Driver. Tracey Brown September 17, 2015 Other. This Chicony USB 2 camera is another Gateway product much like the USB Mass Storage Device which was also released by Gateway that is no longer supported. This is the last USB driver which had been released for the camera.

    Product description

    The HPE Smart Array P410 is HPE's PCI Express 2.0 (PCIe) Serial Attached SCSI (SAS) RAID controller. The low profile, Half-Height card has 8 ports and utilizes DDR2-800 memory. The P410 is ideal for RAID 0/1, 1+0, 5+0 and can be upgraded with the 512MB Battery-Backed Write Cache (BBWC) module and Smart Array advanced via license key for RAID 6 and 6 +0

    Product features

    Description
    HPE's innovative design and integration work of the Smart Array family of products creates end users value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HPE Smart Array family brings an unparalleled return on investment through:
    • Data compatibility among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array controllers

    • Consistent configuration and management tools. All Smart Array products utilize a standard set of management and utility software. These tools minimize TCO by reducing training requirements and technical expertise necessary to install and maintain the HPE Server Storage.

    • Universal hard drive form factor is for use across multiple HPE servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, users are free to deploy and Re-Deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives

    • Pre-Failure warranty means HPE Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HPE support center or refer to the HPE Server documentation

    • The SA-P410 controller supports up to 12 drives depending on the server implementation. Additional drives can be supported with cache and connection to an expander

    • Seamless upgrades from past generations and upgrades to next generation HPE high performance and high capacity SAS Smart Array controllers

    • 6 Gb/s SAS technology delivers high performance and data bandwidth and contains full compatibility with 3 Gb/s SATA technology

    • x8 PCIe Gen 2 host interface technology delivers high performance and data bandwidth up to 2 GB/s maximum bandwidth

    • Modular, Easy-to-Upgrade design lets user to optimize performance by upgrading from 40-bit 256MB cache to 72-bit 512MB BBWC

    • Addition of the battery backed cache upgrade enables BBWC, RAID 5, 5+0, array expansion, logical drive extension, RAID migration, and stripe size migration.

    • Additionally, Smart Array advanced pack license key enables RAID 6 Advanced Data Guarding (ADG), 6+0, advanced capacity expansion, mirror splitting and recombining in offline mode, drive erase, performance Optimization-Degraded reads and read coalescing (VOD)

    • Mix-and-Match SAS and SATA hard drives, lets user to deploy drive technology as needed to fit the computing environment

    • Software consistency among all Smart Array family products: Array Configuration Utility (ACU), Option ROM Configuration for Arrays (ORCA), Systems Insight Manager (SIM), Array Diagnostic Utility (ADU) and SmartStart

    • Low-Profile PCIe form factor - Ships with a full size bracket for deployment in either a Low-Profile or full sized slot

    • Online array expansion (With BBWC upgrade) Software downloader download manager windows 10.

    • Online advanced capacity expansion (With BBWC and Smart Array advanced pack upgrade)

    • Online logical drive extension (With BBWC upgrade)

    • Online RAID level migration (With BBWC upgrade)

    • Online strip size migration (With BBWC upgrade)

    • Offline mirror splitting and recombining (With BBWC and Smart Array advanced pack upgrade)

    • Unlimited global online spare assignment

    • User selectable expand and rebuild priority

    • User selectable RAID level and stripe size

    • User selectable read and write cache sizes

    Eight (8) SAS physical links distributed across 2 internal x4 wide port connectors
    HPE's high performance architecture sets new boundaries of industry performance expectations!
    • 6 Gb/s SAS [(600 MB/s bandwidth per physical link)]

    • x8 6 Gb/s SAS physical links (Compatible with 3 Gb/s SATA )

    • 256MB 40-bit wide DDR2-800 MHz cache upgradeable to 512MB 72-bit wide DDR2-800 MHz Battery-Backed cache provides up to 4.2 GB/s maximum bandwidth

    • x8 PCIe gen 2 host interface provides maximum bandwidth

    • Adobe illustrator cs5 serial download. Gen 2.0

    • Read ahead caching

    • Write-Back caching (With BBWC upgrade)

    NCQ is a technology designed to increase performance of SATA hard disk drives by allowing the individual hard disk to internally optimize the order in which received read and write commands are executed. This can reduce the amount of unnecessary going back-and-forth on the drive's heads, resulting in increased performance for workloads where multiple simultaneous read/write requests are outstanding, most often occurring in server or Storage-Type applications. Without NCQ the drive has to process and complete one command at a time. For NCQ to be enabled, it must be supported and turned on in the controller and in the hard drive itself
    Click here to access the Quickspecs page for HP Serial-ATA (SATA) Hard Drive Option Kits.
    Given the increasing need for high performance and rapid capacity expansion, the SA-P410 controller offers:
    • Up to 38TB of total storage SATA Midline (MDL) Hard Disk Drive (HDD)

    Provides increased server uptime by providing advanced storage functionality:
    • Online RAID level migration (Between any RAID level/with BBWC)

    • Online stripe size migration

    • Online array expansion

    • Online logical drive extension

    • Online drive firmware upgrade

    • Unlimited global online spare

    • Pre-Failure warranty

    The following features offer detection of possible failures before they occur, allowing preventive action to be taken:
    • S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at HPE detects possible hard disk failure before it occurs, allowing replacement of the hard drive before a real failure occurs

    • Drive parameter tracking monitors drive operational parameters, predicting failure and notifying the administrator

    • Dynamic sector repairing continually performs background surface scans on the hard disk drives during inactive periods and automatically remaps bad sectors, ensuring data integrity

    • Smart Array cache tracking monitors integrity of controller cache, allowing Pre-Failure preventative maintenance

    Keeps data available and server running while a failed drive is being replaced; Several fault tolerance configurations are supported including:
    • RAID 6 with ADG: This is the highest level of fault tolerance. It allocates two sets of parity data across drives and allows simultaneous write operations. This level of fault tolerance can withstand two simultaneous drive failures without downtime or data loss

    • RAID 6+0: Supported with min of 8 drives, but would have 4 available. Target benefit is to split RAID across the external boxes

      NOTE: RAID 6, 6+0 is available only with the minimum of 256MB, battery Kit, and Smart Array advanced pack license key option upgrades
    • RAID 5 (Distributed data guarding): This allocates one set of parity data across drives and allows simultaneous write operations. This level of fault tolerance can withstand a single drive failure without downtime or data loss

      • RAID 5 is available on the SA P410/P410i only if the 256MB and battery kit option is used

    • RAID 5+0: This is a RAID 0 array striped across 5 elements. Combines the straight Block-Level striping of RAID 0 with the distributed parity of RAID 5

    • RAID 1, 1+0 (Drive mirroring): This allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file. It is a High-Performance RAID

    Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure
    • Recovery ROM: This feature protects the user from a firmware image corruption by storing a redundant copy of the firmware image. If the active firmware image becomes corrupt, the controller will use the redundant firmware image and continue operating

    • On-Line spares: There is no limit to the number of spare drives that can be installed prior to drive failure. If a failure occurs, recovery begins with an On-Line spare and data is reconstructed automatically

    • DRAM ECC detects and corrects data bit errors

    • BBWC upgrade provides for up to two days of battery power for data cache retention. The data backup duration could be extended anytime the server's auxiliary power is available during system power down

    Consistency and upgradeability make the Smart Array family unique in the industry:
    • GUI based configuration, management and diagnostic software tools

    • Common data format between generations of products

    • Data migration between servers and external StorageWorks Modular Smart Array enclosures

    Software overview

    Description
    • Microsoft Windows 2003 x64 Edition

    • Microsoft Windows 2003 x84 Edition

    • Microsoft Windows 2008 Server x64

    • Microsoft Windows 2008 Server x84

    • Novell Open Enterprise Server, NetWare 6.5

    • Red Hat Enterprise Linux 4 & 5 (x64 & x84)

    • SUSE Linux Enterprise Server 9 (x64 & x84)

    • SUSE Linux Enterprise Server 10 (x64 & x84)

    • SUSE Linux Enterprise Server 11 (x64 & x84)

    • VMWare

    NOTE:Click here to visit our the ProLiant and BladeSystem Server Linux matrix for more Linux OS support and certification information.

    Link to product specification

    Click here to view the specifications page for the HPE Smart Array P410 Controller .

    Links to warranty information

    Click here for detailed information regarding worldwide limited warranty and technical support.

    Click here to check warranty status.

    Links to QuickSpecs

    Information for this Overview is taken from the product QuickSpecs. To access the complete QuickSpecs for this product, select the desired link from the following list:

    • Click here to access the HPE Smart Array P410 Controller Worldwide QuickSpecs in .html format.

    • Click here to access the HPE Smart Array P410 Controller Worldwide QuickSpecs in .pdf format.

    • Click here to view the QuickSpecs homepage, which provides access to the QuickSpecs for other regions/countries.

    Link to drivers, firmware, software and manuals

    Click here to access the drivers, firmware, software and manuals information for HPE Smart Array P410 Controller.

    Link to the list of available documents

    Click here to view a list of documents available for the HPE Smart Array P410 Controller .

    Hp Smart Array Configuration Utility

    Hp smart array controller software reviews

    Legal Disclaimer: Products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may have older product names and model numbers that differ from current models.

    Provide feedback

    Please rate the information on this page to help us improve our content. Thank you!
    1. Was the information on this page helpful?

    Hp Dynamic Smart Array B120i Sata Raid Controller Software

    Please wait while we process your request.